07400015 Tesch F117x01 07400015 Safety Relay 24VAC/DC opening and closure of the contacts. Emergency-Stop Relay F117 fulfils this requirement–EN954-1(3.97)– to the highest safety grade 4 as well. Protection against shorts in the F117 input circuit exists in case of applications involving a 2-channel emergency-stop
The rectangular inductive sensor IS5001 - IS-3002-BPOG from ifm operates with a supply voltage of 10-36 V DC. The output is a positive-switching NO contact. ifm electronic Inductive Block-Style Proximity Sensor
Ethernet switch, 8 TP RJ45 ports, automatic detection of data transmission speed of 10/100 Mbps (RJ45), autocrossing function • RJ45 ports support a transmission speed of 10/100 Mbps • Local diagnostic indicators with LEDs • Auto negotiation and autocrossing detection simplifies installation and setup
Request Callback
Yes! I am Interested
Elan Schmersal SRB-NA-R-C EW 24V 4 NO. 24VDC/VAC Safety Controller
Elan Schmersal SRB-NA-R-C EW 24V 4 NO. 24VDC/VAC Safety Controller Input level. Single-channel control of the expansion module. SRB-NA-R-C.EW via one enabling output of the base.
Request Callback
Yes! I am Interested
ELAN SRB-NA-R-C-24V Safety Relays
Get Best Quote
Approx. Price: Rs 12,000 / PieceGet Latest Price
Product Details:
Brand
ELAN
Usage/Application
Industrial
Model Name/Number
SRB-NA-R-C-24V
Voltage Type
AC
Coil Voltage
24VDC
Type
Voltage Relays
anufacturer: Elan Type: Safety Relay Model: SRB-NA-R-C-24V
Rated Voltage: 24 VDC Rated Current: 120 mA Frequency: 50/60 Hz Contact Rating: 24 VDC, 6 A ; 230 VAC, 6 A Protection Class: IP20 / IP40 Ambient Temperature: -25 … +45 °C Dimensions: 90 X 126.6 X 83 mm
The KL9010 bus end terminal is necessary for data exchange between the Bus Coupler and the Bus TerminThe KL9010 bus end terminal is necessary for data exchange between the Bus Coupler and the Bus Terminals. Each assembly must be terminated at the right hand end with a KL9010 bus end terminal. The bus end terminal does not have any other function or connection facility.als
Incremental, Resolution 360 P/R, 40 mm-dia., Shaft model, NPN open collector, Pre-wired models (0.5 m)Output short-cut protection Power supply reverse polarity protection Operating: -10 to 70 ℃ (with no icing) Storage: -25 to 85 ℃ (with no icing) Destruction: 10 to 500 Hz, 2-mm or 150 m/s2 double amplitude for 11 min 3 times each in X, Y, and Z directions
The IC200GBI001 Network Interface Module has 1024 points of discrete I/O memory, 128 bytes of analog I/O memory, and a 153.6 Kbaud network data rate. It interfaces a Versamax I/O station to a Genius I/O bus. The firmware version of the module is version 3.20. This firmware version can be downloaded to any hardware revision. Its enhanced diagnostic mode can be enabled for use in safety-relevant applications. The power consumption rating of the IC200GBI001 Module is 5 Volts at 250 milliamps or 3.3 Volts at 10 milliamps. The network data rate of the module is 153.6 Kbaud for both the extended and standard baud rate. It uses 3 rotary dials to configure its address and set the communication baud rate. It can be installed on a 35 x 7.5 millimeters conductive DIN rail. The module may be installed horizontally or vertically on the DIN rail. Make sure to remove the power supply before removing the module.
Request Callback
Yes! I am Interested
ICP CON SG-3016 Strain Gauge Signal Conditioner, 10-30VDC, Current/Voltage Out
• Three-way isolation: 1000 Vdc • Accuracy: ±0.1% of full range • Easy to configure input/output range • Three VRs for calibrating accuracy of the input/ output range • Flexible DIN-rail
Request Callback
Yes! I am Interested
PM100RL1A120 Mitsubishi Electric Gate Drivers Ipm Module L1-series
PM100RL1A120 Mitsubishi Electric Gate Drivers IPM MODULE L1-SERIESThe PM100RL1A120 is a 1200V, 100A Intellimod intelligent power module. It is isolated base module designed for power switching applications operating at frequencies to 20KHz. Built in control circuits provide optimum gate drive and protection for the IGBT and free wheel diode power devices.
7-Pac circuit configuration
Complete output power circuit
Gate drive circuit
Short circuit protection
Overtemperature protection using on chip temperature sensing
Undervoltage protection
Low loss using full gate CSTBT IGBT chip
Request Callback
Yes! I am Interested
TM5ACTB12 Schneider Electric Modicon Tm5, Terminal Block, 12 Contacts, White,
PSS SB2 3006-3 ETH-2 COMPACT SAFETY SYSTEM WITH SAFETYBUS P CONNECTION 3rd generation compact safety system with SafetyBUS p and Ethernet interfaces. Suitable for safety-related functions because of its multi-channel diverse structure.
Request Callback
Yes! I am Interested
EK1100 Ether CAT Coupler Beckhoff Power Supply Terminal
EK1100 | EtherCAT Coupler Beckhoff The EK1100 EtherCAT Coupler is the link between the EtherCAT protocol at fieldbus level and the EtherCAT Terminals. The coupler converts the passing telegrams from Ethernet 100BASE-TX to E-bus signal representation. A station consists of a coupler and any number of EtherCAT Terminals that are automatically detected and individually displayed in the process image.
PILZ-827225 - Single-phase voltage monitoring relay - measuring inputs are not polarity-sensitive - Pilz (PMDs S1UM) - S1UM 24Vdc UM 0.1-500Vac/DC UP Voltage monitoring relay, to monitor min. and max. voltage values, 12 measuring ranges 0.1 - 500 V AC/DC selectable, 0.40 -400 Hz, width = 22.5 mm, UB = 24 V DC, measuring inputs are notpolarity-sensitive.
Request Callback
Yes! I am Interested
IRIPROX-3I-EI-H-5-5 C&S make compact Over-current protection relay
IRIPRO Series offers a compact Over-current protection solution for distribution/feeder segment
Request Callback
Yes! I am Interested
Eurotherm Make 3508 Controller for Furnace Control FC1511002348
Get Best Quote
Approx. Price: Rs 48,600 / PieceGet Latest Price
Product Details:
Control Type
PID
Frequency
50/60 Hz
Voltage
24 VAC/DC
Mounting Type
Panel
Brand
Eurotherm BY Schneider
Control output Type
Relay
Eurotherm PID used a sensor to detect the Process Value (PV) such as a thermocouple or pressure sensing device. A controller to provide control of that process, referred to in the overhead as the term PID. An output to an actuator or device to control the input stimulus to that process, such as heat.
TLS-GD2 Guard Locking Switch is a positive-mode, tongue-operated interlock switch. It locks a machine guard closed until power is isolated then keeps the power isolated while the guard is open. The TLS-GD2 has three safety (N.C.) contacts and two auxiliary (N.O.) contacts.