We are a leading Wholesale Trader of ue410-4r04 safety relays, elan safety relay srb-na-st-24vdc, mvi69-mcm profibus connector, siemens 6dr2804-8b interface relay module with 2 contacts, flex 16-point digital output module cat no: 1794-ob16 and pilz pnoz s4 24vdc id no: 750104 safety relay from Bengaluru, India.
Elan SRB-NA-ST-24 VDC Safety Relay which was tested by us and is fully functional.ELAN SRB-NA-ST/Z-24VDC SAFETY RELAY ; Supply Voltage: 24 VDC, 250 VAC ; Rated Current: 120 mA ; Frequency: 50/60 Hz ; Contact Rating: 24 VDC, 6 A ; 230 VAC, 6 A
The MVI69-MCM Modbus Master/Slave Network Interface Module allows Rockwell Automation® CompactLogix™ Programmable Automation Controllers (PACs) and MicroLogix™ 1769-LRP Programmable Logic Controllers (PLCs) to interface with Modbus-compatible devices. Compatible devices include not only Modicon® PLCs but also a wide assortment of thirdparty devices found in nearly every industry.
Request Callback
Yes! I am Interested
SIEMENS 6DR2804-8B Interface relay module with 2 contacts
Get Best Quote
Approx. Price: Rs 12,000 / PieceGet Latest Price
Product Details:
Usage/Application
Industrial
Brand
Siemens
Channels
16
Number Of Poles
2 Pole
Relay Type
Interface
Coil Voltage
220 V
Current Output
4A
Siemens Relay Output 6DR2804-8B or other Temperature Controllers Interface relay module with 2 contacts
Request Callback
Yes! I am Interested
FLex 16-Point Digital Output Module Cat No: 1794-OB16
MCR-C-UI-UI-DCI Phoenix Contact MCR 3-way signal conditioner, with configurable input/output,MCR-C-UI-UI-DCI PHOENIX CONTACT Signal conditioner (2810939)
EtherCAT Terminal, 8-channel analog input, temperature, thermocouple, 16 bit The EL3318 analog input terminal allows eight thermocouples to be connected directly and is thus particularly suitable for space-saving use in control cabinets. The EtherCAT Terminal circuit can operate thermocouple sensors using the 2-wire technique. A microprocessor handles linearization across the whole temperature range, which is freely selectable. The error LEDs indicate a broken wire. Compensation for the cold junction is made through an internal temperature measurement at the terminal. The EL3318 can also be used for mV measurement.
The K-ADP-USB is a programming adapter that connects the USB interface of a PC for the PACTware operating software and can be used to program K-, E- and H system devices via the programming socket on the front panel of these devices. As K-, E- and H-System devices have formerly been equipped with programming sockets with different standard dimensions (3.55 mm x 18.3 mm, see drawing, pos. 3 – newer devices 3.5 mm x 14 mm, pos. 1), an adapter (pos. 2) for the parameterisation of all devices is attached to K-ADPUSB